<p class="MsoNormal"><span lang="EN-US">1</span><span style="font-family:宋体;
mso-ascii-font-family:"Times New Roman";mso-hansi-font-family:"Times New Roman"">)从安全原则考虑,信号中断时,给水阀应处于全开位置较为安全,以防锅炉烧干,因此给水阀选择气关阀;蒸汽阀此时应处于全开状态以防锅炉内压力过大引起事故,因此蒸汽阀选择气关阀。</span></p>
<p class="MsoNormal"><span lang="EN-US"> </span></p>
<p class="MsoNormal" style="text-indent:21.75pt"><span lang="EN-US">2</span><span style="font-family:宋体;mso-ascii-font-family:"Times New Roman";mso-hansi-font-family:
"Times New Roman"">)液位控制器</span><span lang="EN-US">:</span><span style="font-family:宋体;mso-ascii-font-family:"Times New Roman";mso-hansi-font-family:
"Times New Roman"">阀为气关阀,则</span><span lang="EN-US">kv </span><span style="font-family:宋体;mso-ascii-font-family:"Times New Roman";mso-hansi-font-family:
"Times New Roman"">选“-”,进水量增多时,液位上升,则</span><span lang="EN-US">kp</span><span style="font-family:宋体;mso-ascii-font-family:"Times New Roman";mso-hansi-font-family:
"Times New Roman"">选“</span><span lang="EN-US">+</span><span style="font-family:
宋体;mso-ascii-font-family:"Times New Roman";mso-hansi-font-family:"Times New Roman"">”,根据负反馈原则,</span><span lang="EN-US">kc</span><span style="font-family:宋体;mso-ascii-font-family:"Times New Roman";
mso-hansi-font-family:"Times New Roman"">应为“</span><span lang="EN-US">+</span><span style="font-family:宋体;mso-ascii-font-family:"Times New Roman";mso-hansi-font-family:
"Times New Roman"">”,所以液位控制器应选择正作用。</span></p>
<span lang="EN-US" style="font-size:10.5pt;mso-bidi-font-size:12.0pt;font-family:
"Times New Roman","serif";mso-fareast-font-family:宋体;mso-font-kerning:1.0pt;
mso-ansi-language:EN-US;mso-fareast-language:ZH-CN;mso-bidi-language:AR-SA"> </span><span style="font-size:10.5pt;
mso-bidi-font-size:12.0pt;font-family:宋体;mso-ascii-font-family:"Times New Roman";
mso-hansi-font-family:"Times New Roman";mso-bidi-font-family:"Times New Roman";
mso-font-kerning:1.0pt;mso-ansi-language:EN-US;mso-fareast-language:ZH-CN;
mso-bidi-language:AR-SA">压力控制器:阀为气关阀,则</span><span lang="EN-US" style="font-size:
10.5pt;mso-bidi-font-size:12.0pt;font-family:"Times New Roman","serif";
mso-fareast-font-family:宋体;mso-font-kerning:1.0pt;mso-ansi-language:EN-US;
mso-fareast-language:ZH-CN;mso-bidi-language:AR-SA">kv </span><span style="font-size:10.5pt;mso-bidi-font-size:12.0pt;font-family:宋体;mso-ascii-font-family:
"Times New Roman";mso-hansi-font-family:"Times New Roman";mso-bidi-font-family:
"Times New Roman";mso-font-kerning:1.0pt;mso-ansi-language:EN-US;mso-fareast-language:
ZH-CN;mso-bidi-language:AR-SA">选“-”,蒸汽量加大时,压力减小,则</span><span lang="EN-US" style="font-size:10.5pt;mso-bidi-font-size:12.0pt;font-family:"Times New Roman","serif";
mso-fareast-font-family:宋体;mso-font-kerning:1.0pt;mso-ansi-language:EN-US;
mso-fareast-language:ZH-CN;mso-bidi-language:AR-SA">kp</span><span style="font-size:10.5pt;mso-bidi-font-size:12.0pt;font-family:宋体;mso-ascii-font-family:
"Times New Roman";mso-hansi-font-family:"Times New Roman";mso-bidi-font-family:
"Times New Roman";mso-font-kerning:1.0pt;mso-ansi-language:EN-US;mso-fareast-language:
ZH-CN;mso-bidi-language:AR-SA">选“-”,根据负反馈原则,</span><span lang="EN-US" style="font-size:10.5pt;mso-bidi-font-size:12.0pt;font-family:"Times New Roman","serif";
mso-fareast-font-family:宋体;mso-font-kerning:1.0pt;mso-ansi-language:EN-US;
mso-fareast-language:ZH-CN;mso-bidi-language:AR-SA">kc</span><span style="font-size:10.5pt;mso-bidi-font-size:12.0pt;font-family:宋体;mso-ascii-font-family:
"Times New Roman";mso-hansi-font-family:"Times New Roman";mso-bidi-font-family:
"Times New Roman";mso-font-kerning:1.0pt;mso-ansi-language:EN-US;mso-fareast-language:
ZH-CN;mso-bidi-language:AR-SA">应为“-”,所以压力控制器应选择反作用。</span><br>