<p class="MsoNormal">
歌舞娱乐放映游艺场所建筑消防设施配置要点有:<span></span>
</p>
<p class="MsoNormal">
(<span>1</span>)应配置室外消火栓给水系统。<span></span>
</p>
<p class="MsoNormal">
(<span>2</span>)应配置室内消火栓给水系统,层数不超过<span>5</span>层或体积不大于<span>10000㎡</span>的可不设。<span></span>
</p>
<p class="MsoNormal">
(<span>3</span>)应配置自动喷水灭火系统,层数在地上一至三层且任一层建筑面积不大于<span>300m</span>²的地上歌舞、娱乐、放映、游艺场所可不设。<span></span>
</p>
<p class="MsoNormal">
(<span>4</span>)应配置火灾自动报警系统。<span></span>
</p>
<p class="MsoNormal">
(<span>5</span>)应配置防排烟系统,但层数在地上一至三层且房间面积不大于<span>100m</span>²的可不设。<span></span>
</p>
<p class="MsoNormal">
(<span>6</span>)应配置安全疏散设施。<span></span>
</p>
<p class="MsoNormal">
(<span>7</span>)应配置建筑灭火器。<span></span>
</p>